FIBER CABLES & ACCESSORIES
Home > Products > 10Gb > Fiber Cable & Accessories

GIGALINE F0 INDOOR DUPLEX - DX 100 / DX 500 / DX 625Top

Structure

  1. Two semi-tight buffered fibers in figure 8-shape ripcord. One core red, the other yellow (E9?10/125), green (G50/125) or blue (G62.5/125)
  2. Strain relief: aramid yarn
  3. Sheath: halogen-free compound
  4. Colour: orange (multimode), yellow (single mode)
Application
:Patch cord, suitable for direct connection and for splicing
FIBERS CORE ARTICLE NO.
2 G50/125 900 8DA20003
2 G50/125 OM3 900 8DA50003

GIGALINE F0 INDOOR MINI-BREAKOUT - M100 / M500 / M625Top

Structure

  1. Up to 12 900m semi-tight buffered fibers under a common sheath color code acc. To EIA/TIA 598C blue (1), orange (2), green (3), brown (4), grey (5), white (6), red (7), black (8), yellow (9), violet (10), pink (11), turquoise (12)
  2. Strain relief: aramid yarn
  3. Sheath: halogen-free compound
  4. Colour: orange (multimode), yellow (single mode)
Application
:
  1. Suitable for direct connection and for splicing.
  2. Particularly suitable for horizontal cabling for installation in conduits and ducts.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
6 G/E 5.9 8MA50013
12 G/E 7.0 8MA50016

GIGALINE F0 INDOOR BREAKOUT - AT100 / AT500 / AT625Top

Structure

  1. Up to 12 900m semi-tight buffered fibers breakout design ( 2.1mm) stranded under a common outer sheath. Orange (multi mode) or yellow (Single mode)
  2. Strain relief: aramid yarn
  3. Ripcord under the sheath
  4. Sheath: halogen-free compound
  5. Colour: orange (multimode), yellow (single mode)
Application
:
  1. Suitable for direct connection and for splicing.
  2. Particularly suitable for horizontal cabling for installation in conduits and ducts.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
6 G/E 8.2 8BA50013
12 G/E 12.5 8BA50016

GIGALINE LWL UNIVERSAL MULTITUBETop

Application
:
  1. Suitable for splicing. Campus/backbone cabling, for indoors installation in case of increased mechanical requirements and rodent hazard;
  2. for outdoor installation in dry conduits; building entry without additional transition points (splices) possible.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
6 G/E 8.2 8BA50013
12 G/E 12.5 8BA50016

GIGALINE F0 UNIVERSAL CIRCUITTop

Application
:
  1. Suitable for splicing. Campus/backbone cabling, for indoors installation in case of increased mechanical requirements and rodent hazard;
  2. for outdoor installation in dry conduits; building entry without additional transition points (splices) possible.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
1x6 10.3 8UA500B3
1x12 10.3 8UA500B6
1x24 10.8 8UA500B9

GIGALINE F0 UNIVERSAL ARMOUREDTop

Application
:
  1. Suitable for splicing. Campus/backbone cabling, for indoors installation in case of increased mechanical requirements and rodent hazard;
  2. for outdoor installation in dry conduits; building entry without additional transition points (splices) possible.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
1x6 12.5 8UA500D3
1x12 12.5 8UA500D6
1x24 12.5 8UA500D9

GIGALINE F0 OUTDOOR SINGLETop

Application
:
  1. Suitable for splicing.
  2. Out door cable for installation directly in the ground, in ducts or in conduits; for MAN (City Networks) and LAN (campus/backbone) applications.
FIBERS OUTER ARTICLE NO.
mm(approx.) OM3 G50/125
1x6 7.0 8AA500A3
1x12 7.0 8AA500A6
1x24 7.5 8AA500A9